THE 5-SECOND TRICK FOR DP50RB LOGIN

The 5-Second Trick For Dp50rb login

The 5-Second Trick For Dp50rb login

Blog Article

Guidance 4D probe; understand the probe through the ID code; swap the 4D generate sign through the  electrical relay to make the 4D probe perform normally. four.2.2 Principal board The key board can be divided into two areas: entrance-stop of the leading board and again-conclusion of the primary board.

The person is just not allowed to open the addresses and panel in the system, neither Be aware: gadget disassemble is allowed. To make sure the procedure general performance and basic safety, only Mindray engineers or engineers licensed by Mindray can execute maintenance.

Get an entire and prolonged check out of the anatomical composition by panoramic imaging coupled with velocity indicator and forward/backward scan capability generating scanning less difficult, smoother and much more controllable.

This handbook may perhaps referring to information guarded by copyright or patents and isn't going to Express any license under the patent legal rights or copyright of Mindray, or of Other people. Webpage nine: Assertion

Slice off cable ties connecting the primary device around the Exhibit by diagonal cutting pliers, and after that pull out the corresponding cable plugs.

Mindray’s new era of black & white ultrasound technique, DP-fifty Pro, is equipped with advanced imaging technologies allowing deeper penetration and faster image acquisition with bigger resolution.

The chapter supplies the strategy to confirm main function and general performance of item. This is certainly only utilized for reference, not preventive execution. Perform examining and tests of the portion shall be performed by Mindray support engineers as well as consumer with each other. Web site 66: Typical Test

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ permits correct viewing of picture from distance iWorks™ Protocol assists standardize workflow and decrease exam instances

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Exam Step: Do adjustments as the way in which in screening the maximum depth. Report the distance by 20mm Just about every phase within the longitudinal targets line utilizing the measurement caliper; Pick out the worth with the greatest error (to 20mm), work out the accuracy utilizing the formulation down below The measurement caliper needs to be positioned on the higher fringe of the target, NOTE:... Website page 79 Transverse geometric positioning accuracy  Test Phase: Include the scan floor in the phantom with water or few gel, Carefully Make contact with the probe With all the scan surface Regulate the depth, earning the transverse targets for being displayed in the picture. Alter the focus place being posited beside the transverse targets (the standard will not be obvious) Adjust parameters like obtain, TGC, building Just about every transverse targets to generally be clearly displayed. Web page 80 five.5.2.4 Blackout Space Test Stage: Include the scan floor in the phantom with water or couple gel, Carefully Make contact with the probe Using the scan area Modify the depth at a decrease price, and set the main target at the closest place to the scan surface area. Lower the value of parameters like AP, Obtain until eventually the history sound just could be noticed. Website page eighty one: Computer software Enhance And Routine maintenance

The DP-50 Qualified can be an impressive, higher-efficiency Ultrasound System engineered that will help you obtain the insights you would like. The Method’s highly effective engine and higher-speed processing supply exceptional impression good quality and a whole details management Answer.

Find superior diagnostic data by means of extended look at with the anatomical composition on all linear probes

Take note: Ahead of inserting the Dp50rb connector into your probe port, inspect the connector pin. In case the pin is bent, don't utilize the probe until it's been inspected / fixed / changed. Setting up Peripherals For the products of the supported peripherals, you should check with “2.

After changing the CPU module, important file has to be created once again based on the new MAC address and published into HDD in the device. Or else, the configuration purpose of the product or service are going to be lost. Immediately after removing the CPU module, Clear away panhead screws with washers (12 M3X6) mounted on the key device box, you can take off the board. Webpage 118 Figure 8-29 Disassemble the User interface Assembly (1) Maintain the higher edge of control panel assembly, and open up up the user interface. Figure eight-thirty Disassemble the User interface Assembly (2) Right after eliminating a single countersunk head self-tapping screw PT3X10 mounted around the control panel and take out the plug of the keyboard and the principle unit connecting cables, you could potentially eliminate the control panel assembly.

A sensible new shape, Increased mobility and effortless operation make DP-fifty well suited for all clinical options.

Report this page